Relay defaults to an energized state.
Pulsing the output de-energizes it for its designated pulse time (or pulses
the output off). At the end of the pulse time, the output reenergizes. (The
output responds the same upon a valid egress, a valid card read, and/or a manual
pulse command.
Energizing a relay turns the relay off (LED off).
De-energizing a relay turns the relay on (LED on).
Normally Open circuit acts as a Normally Closedcircuit. Normally Closed circuit
acts as a Normally Open circuit.
Create an ADV for Each Output Point
You must configure an ADV for each of the output
[control] points that you will be using.
5 Click the Add button in the ADV area of the
window to open the Abstract Device Record -
Control Point window (below).
NOTE: Within the Abstract Device Records, output points
are considered "Control Points." Input points are consid-
ered "Monitor Points," and readers are considered
"Entrances."
Programming